WatchGas SST4 Micro – 4-Gas Detector (Low Power Catalytic LEL)

Compact multi-gas detector (O2, LEL, CO, H2S or SO2) with a low-power catalytic LEL sensor, about 48 h battery life, induction charging and NFC. IP65/68, ATEX/IECEx Zone 0.

  • Genuine products from leading safety brands
  • Delivery across Saudi Arabia
  • Datasheets & certificates available on request
  • Bulk and project pricing for companies
SKU: WATCHGAS-SST4-MICRO Category: Tag: Brand:

Compact multi-gas detector (O2, LEL, CO, H2S or SO2) with a low-power catalytic LEL sensor, about 48 h battery life, induction charging and NFC. IP65/68, ATEX/IECEx Zone 0.

Specifications

LEL sensor Low Power Catalytic, 0–100 % LEL, res. 1 % LEL; alarms low 10 % / high 20 %
O2 sensor 0–25 % vol, resolution 0.1 % vol; alarms low 19.5 % / high 23.5 %
CO sensor 0–2000 ppm, resolution 1 ppm; alarms low 35 / high 200 ppm; TWA 20 ppm, STEL 100 ppm
H2S sensor 0–500 ppm, resolution 0.1 ppm; alarms low 10 / high 15 ppm; TWA 10 ppm, STEL 15 ppm
SO2 sensor 0–100 ppm, resolution 0.1 ppm; alarms low 5 / high 10 ppm; TWA 2 ppm, STEL 5 ppm
Typical battery life 48 h
Charging time 2–3 hours (induction charger included)
Size 103.9 × 62.4 × 26.1 mm (+4 mm with alligator clip)
Weight 184 g
Operating temperature -40 to +60 °C
Humidity 5–95 % RH (non-condensing)
Charging Induction (wireless) charging
Event logging 100 events
Data logging 6 months
Ingress protection IP65 / IP68
Communication NFC – WatchGas SST App (bump, calibrate, assign, download event and data logs)
Calibration interval 6 months (industry standard)
Alarms 95 dB at 30 cm; High, HighHigh, Low, LowLow, TWA and STEL configurable via SST Dock or App; backlit display
Display units ppm, % vol, mg/m³, % LEL; correction factors via App
Warranty 2 years
Accessories External filter SST-MICRO-XFIL-10; lanyard bar SST4-POUL-10; universal cradle charger SST-IND-S; 5-way stackable charging cradle SST-STACK-CHR; aspirator bulb/pump 7189201; aluminium kit 460039; SST Dock; SST RTR web reporting software

Standards & Certifications

  • ATEX / IECEx / UKEX (LEL-LPC & LEL-CAT): II 1 G Ex ia IIC T4 Ga; I M1 Ex ia I Ma
  • ATEX / IECEx / UKEX (LEL-IR): II 1 G Ex ia op is IIC T4 Ga; I M1 Ex ia op is I Ma
  • North America: Class I Division 1 Groups A, B, C, D T4
  • US: Class I Zone 0 AEx ia IIC T4 Ga (IR: AEx ia op is IIC T4 Ga)
  • Canada: Ex ia IIC T4 Ga (IR: Ex ia op is IIC T4 Ga)
  • EN 50270:2015+AC:2016
  • EN 301 489-1 V2.2.3
  • EN 301 489-3 V2.1.1
  • RoHS EN 63000:2018

For pricing and availability, please request a quotation.

Chat with usWhatsApp · Quick reply