Sofamel PAT-MPL – Set with MPL clamps for substations

MPL aluminium clamps with screw tightening; wide range of cable sections and Lengths available to suit According to IEC 61230 standard. 5-45 mm 0-45 mm Max. 45 mm 0-45 mm Max. 45 mm 20-25 mm High-voltage earthing equipment is supplied without an insulating hot stick.

  • Genuine products from leading safety brands
  • Delivery across Saudi Arabia
  • Datasheets & certificates available on request
  • Bulk and project pricing for companies
SKU: SOFAMEL-30906-PAT-MPL Category: Tag: Brand:

MPL aluminium clamps with screw tightening; wide range of cable sections and Lengths available to suit According to IEC 61230 standard. 5-45 mm 0-45 mm Max. 45 mm 0-45 mm Max. 45 mm 20-25 mm High-voltage earthing equipment is supplied without an insulating hot stick.

Specifications

Short-circuit current (ICC) requirements and reach.
Short-circuit current (ICC) 40 kA/1s
Short-circuit current (ICC) 30 kA/1s
Composed of 3 MPL aluminium alloy clamps with screw tightening. For cylindrical conductors with diameters between 5 and 45 mm, and flat bars.; 3 copper cables with PVC insulation. Section and length depending on model.; 3 TT-50 earthing lathes.; 3 bags for storing and transporting the equipment.
Ref. PAT-MPL/05006 Code 680176; Length (m): 6
Ref. PAT-MPL/05007 Code 680177; Cable section (mm²): 50; Length (m): 7; Short-circuit current Max. ICC: 12 kA/1s
Ref. PAT-MPL/05008 Code 680178; Cable section (mm²): 50; Length (m): 8; Short-circuit current Max. ICC: 12 kA/1s
Ref. PAT-MPL/05009 Code 680179; Cable section (mm²): 50; Length (m): 9; Short-circuit current Max. ICC: 12 kA/1s
Ref. PAT-MPL/05010 Code 680180; Cable section (mm²): 50; Length (m): 10; Short-circuit current Max. ICC: 12 kA/1s
Ref. PAT-MPL/07006 Code 680186; Cable section (mm²): 70; Length (m): 6; Short-circuit current Max. ICC: 19 kA/1s
Ref. PAT-MPL/07007 Code 680187; Cable section (mm²): 70; Length (m): 7; Short-circuit current Max. ICC: 19 kA/1s
Ref. PAT-MPL/07008 Code 680188; Cable section (mm²): 70; Length (m): 8; Short-circuit current Max. ICC: 19 kA/1s
Ref. PAT-MPL/07009 Code 680189; Cable section (mm²): 70; Length (m): 9; Short-circuit current Max. ICC: 19 kA/1s
Ref. PAT-MPL/07010 Code 680190; Cable section (mm²): 70; Length (m): 10; Short-circuit current Max. ICC: 19 kA/1s
Ref. PAT-MPL/09506 Code 680196; Cable section (mm²): 95; Length (m): 6; Short-circuit current Max. ICC: 25 kA/1s
Ref. PAT-MPL/09507 Code 680197; Cable section (mm²): 95; Length (m): 7; Short-circuit current Max. ICC: 25 kA/1s
Ref. PAT-MPL/09508 Code 680198; Cable section (mm²): 95; Length (m): 8; Short-circuit current Max. ICC: 25 kA/1s
Ref. PAT-MPL/09509 Code 680199; Cable section (mm²): 95; Length (m): 9; Short-circuit current Max. ICC: 25 kA/1s
Ref. PAT-MPL/09510 Code 680200; Cable section (mm²): 95; Length (m): 10; Short-circuit current Max. ICC: 25 kA/1s
Ref. PAT-MPL/12006 Code 680206; Cable section (mm²): 120; Length (m): 6; Short-circuit current Max. ICC: 30 kA/1s
Ref. PAT-MPL/12007 Code 680207; Cable section (mm²): 120; Length (m): 7; Short-circuit current Max. ICC: 30 kA/1s
Ref. PAT-MPL/12008 Code 680208; Cable section (mm²): 120; Length (m): 8; Short-circuit current Max. ICC: 30 kA/1s
Ref. PAT-MPL/12009 Code 680209; Cable section (mm²): 120; Length (m): 9; Short-circuit current Max. ICC: 30 kA/1s
Ref. PAT-MPL/12010 Code 680210; Cable section (mm²): 120; Length (m): 10; Short-circuit current Max. ICC: 30 kA/1s

Standards & Certifications

  • IEC 61230

For pricing and availability, please request a quotation.